SSID name of the primary 2.4GHz Wi-Fi access point to connect to. Please note that 5G bandwidth networks not supported. Can be up to 25 characters long.
default = aya_ssid
SSID 1:
Wi-Fi password to the primary network above. Can be up to 25 characters long.
default = aya_pass
Password 1:
SSID name of the secondary 2.4GHz Wi-Fi access point to connect to if the primary network is not available. Please note that 5G bandwidth networks not supported. Can be up to 25 characters long.
default = [empty]
SSID 2:
Wi-Fi password to the secondary network above. Can be up to 25 characters long.
default = [empty]
Password 2:
Determines the default Wi-Fi mode in which the device begins following the boot. In the STA
mode the device will try to maintain a connection to one of the saved wireless networks. In the AP
mode the device will serve as an independent Access Point, allowing other wireless devices to connect to it. The two modes can be arbitrarily switched during runtime.
default = STA
Default mode:
If a dynamic IP mode is selected, then the local network IP address, Gateway, DNS and Subnet mask assigned to the device are decided automatically by the router. If static is selected, then the parameters entered below are prioritized.
default = Dynamic
STA IP:
Device's local network IP address. Only applicable if Static
IP Mode is selected and only used if the provided address is available.
default = 192.168.1.255
IPv4:
Local network gateway. Only applicable if Static
IP Mode is selected.
default = 192.168.1.1
Gateway:
Local network subnet mask. Only applicable if Static
IP Mode is selected.
default = 255.255.255.0
Subnet mask:
IP address of the preferred DNS server. Only applicable if Static IP Mode is selected and an internet connection is available.
default = 8.8.8.8
(Google Public DNS)
DNS:
External IP address as identified by the device. Only available in case of active internet connection.
default = 1.1.1.1
External IP:
Allow or disable connection to the MQTT broker for publishing sensor readings, output state changes or remote control.
default = Disabled
learn more...
Connection:
Allow or disable subscribing to and receiving MQTT messages for remote control via MQTT.
default = Enabled
learn more...
Subscription:
Web or IP address of the MQTT broker.
default = 192.168.1.200
Broker address:
Listener port of the MQTT broker. Only non-SSL listeners are supported.
default = 1883
Port:
Client user name to the MQTT broker. Can be up to 40 characters long.
default = mqtt_user
User:
Client password to the MQTT broker. Can be up to 25 characters long.
default = mqtt_pass
Password:
1. level of topic string used for communication with the device (required). Can be up to 25 characters long and should not contain special characters.
default = my_uni
learn more...
Topic Level 1:
2. level of topic string used for communication with the device (optional). Can be up to 25 characters long and should not contain special characters.
default = [empty]
learn more...
Topic Level 2:
3. level of topic string used for communication with the device (optional). Can be up to 25 characters long and should not contain special characters.
default = [empty]
learn more...
Topic Level 3: